Cited 0 time in
1 GW급 부유식 해상풍력발전단지의 배치 최적화에 관한 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박진수 | - |
| dc.contributor.author | 박병원 | - |
| dc.contributor.author | 성홍근 | - |
| dc.date.accessioned | 2025-12-29T21:30:54Z | - |
| dc.date.available | 2025-12-29T21:30:54Z | - |
| dc.date.issued | 2025-03 | - |
| dc.identifier.issn | 1738-3935 | - |
| dc.identifier.issn | 2713-9999 | - |
| dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/11074 | - |
| dc.description.abstract | This study provides a foundation for the conceptual design and performance analysis of a large-scale centralized offshore green hydrogen production and storage platform. It focuses on optimizing the layout of a 1 GW-class floating offshore wind farm to maximize power generation while minimizing costs. To achieve this objective, a site near the Donghae gas plant in the East Sea was selected as a candidate location for the floating offshore wind farm. Wind resource analysis was conducted using MERRA-2 reanalysis data provided by NASA. The Jensen wake model was applied, and an optimization objective function was developed that considered both the wind occurrence frequencies by direction and in-field cable costs of the farm. Continuous Ant Colony Optimization was performed. Consequently, the power generation estimates were calculated by statistically considering the actual wind occurrence frequencies at the farm sites, ensuring realistic power production results. | - |
| dc.format.extent | 12 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국신·재생에너지학회 | - |
| dc.title | 1 GW급 부유식 해상풍력발전단지의 배치 최적화에 관한 연구 | - |
| dc.title.alternative | Layout Optimization Study for a 1 GW Floating Offshore Wind Farm | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.7849/ksnre.2025.2029 | - |
| dc.identifier.bibliographicCitation | 신재생에너지, v.21, no.1, pp 64 - 75 | - |
| dc.citation.title | 신재생에너지 | - |
| dc.citation.volume | 21 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 64 | - |
| dc.citation.endPage | 75 | - |
| dc.identifier.kciid | ART003184473 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Donghae gas field | - |
| dc.subject.keywordAuthor | 배치 최적화 | - |
| dc.subject.keywordAuthor | 부유식 해상풍력발전단지 | - |
| dc.subject.keywordAuthor | Layout optimization | - |
| dc.subject.keywordAuthor | 연속적 개미 군집 최적화 | - |
| dc.subject.keywordAuthor | 동해 가스전 | - |
| dc.subject.keywordAuthor | Floating offshore wind farm | - |
| dc.subject.keywordAuthor | Continuous ant colony optimization | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.